Six integration modes, a normalization pipeline, and governance controls for enterprise-grade EHR interoperability.
Six bidirectional integration modes for comprehensive EHR connectivity.
EHR-embedded app launch with patient context, user context, and OAuth2 token exchange.
Standards
EHRs
Epic, Cerner, Allscripts
Scheduled and on-demand pull of FHIR R4 resources from EHR FHIR APIs.
Standards
EHRs
Epic, Cerner, athenahealth, MEDITECH
Real-time push notifications when patient data changes in the EHR.
Standards
EHRs
Epic (mychart), Cerner
Bidirectional HL7v2 message processing for ADT, ORU, ORM, MDM, and DFT messages.
Standards
EHRs
MEDITECH, NextGen, eClinicalWorks, Legacy systems
Secure Direct messaging for clinical document exchange between providers.
Standards
EHRs
Any Direct-enabled EHR
Automated C-CDA document ingestion with structured data extraction.
Standards
EHRs
All ONC-certified EHRs
Integration status and patient coverage for supported EHR platforms.
| EHR Platform | Integration Mode | Patient Coverage | Status |
|---|---|---|---|
| Epic | SMART on FHIR + REST patterns | — | Adapter / planned live |
| Oracle Cerner | SMART on FHIR + REST patterns | — | Adapter / planned live |
| Allscripts | SMART Launch + REST patterns | — | Adapter / planned live |
| athenahealth | FHIR REST patterns | — | Adapter / planned live |
| MEDITECH | HL7v2 bridge patterns | — | Planned |
| NextGen | HL7v2 bridge patterns | — | Planned |
| eClinicalWorks | HL7v2 bridge patterns | — | Planned |
Seven-stage pipeline to normalize clinical data from heterogeneous EHR sources.
Raw HL7v2, FHIR, C-CDA, and API data received and queued.
Message type detection, schema validation, and field extraction.
Source terminology mapped to SNOMED CT, LOINC, RxNorm, and ICD-10.
Patient matching and resource deduplication using probabilistic algorithms.
Provenance recording, versioning, and FHIR resource assembly.
FHIR profile conformance validation and error flagging.
Persistent storage with full audit trail.
Six governance controls for secure and compliant EHR integration.
Consent Enforcement
Patient consent policies enforced at the integration layer before any data exchange.
Rate Limiting
Per-tenant and per-integration rate limits to prevent API abuse and ensure fair usage.
Transform Auditing
Every data transformation logged with source, target, mapping rules, and timestamp.
Error Handling
Structured error capture, retry logic, and dead-letter queue for failed messages.
Version Control
Integration configuration versioned with rollback capability.
Access Control
Per-integration RBAC — only authorized services and users invoke each integration.
Our integration team provides dedicated support for FHIR API setup, EHR configuration, and data migration.